Files
tpms-schrader-eg53ma4-sim/docs/TROUBLESHOOTING.md
T
czcionka e183d23950
check / check-without-hardware (push) Successful in 6m45s
Docs and code: translate Polish comments, messages and documentation to English
- README, CHANGELOG, RELEASE_NOTES, THIRD_PARTY_NOTICES and docs/*.md
  translated to English; cross-markdown anchors updated
- C/C++/Python/shell comments and user-facing messages translated
- identifiers, protocol names, commands and literals unchanged
- native tests re-verified: 24/24 PASS; tpms_frame.py self-test PASS
2026-10-30 18:01:32 +00:00

3.7 KiB
Raw Blame History

Troubleshooting

Work one change at a time and record the measurement. Do not switch OOK/FSK, flags, IDs, or intervals randomly. The base firmware has no FSK mode.

Symptom Possible cause Measurement / check Repair
ERROR: no CC1101 poor supply, CS/SPI, module is not 433 MHz 3.3 V across VCC-GND; continuity SCK/MISO/MOSI/CS = 4/5/6/7; module marking fix wiring, shorten SPI, use the correct module
Reset during TX 3.3 V droop, weak wires voltage at the ESP32/CC1101 during send, brownout log fix the supply and 47–100 µF at the module; do not raise the PA
TX-ERR underflow, unfinished TX, wrong CC1101 configuration log for each wheel; MARCSTATE/registers in HIL check SPI and supply; save the log for analysis, do not mask the error
USB/UART does not respond console window too short, wrong baud/port, charge-only cable 115200 8N1, reset, correct /dev/ttyACM* or /dev/ttyUSB* type stay 300 right after startup; use a data cable
ID change disappears NVS write error, full flash OK: saved message, restart and info do not continue on an NVS error; check flash/supply
ID rejected duplicate, 0, FFFFFF, wrong length six hex digits and info transmit four unique IDs from 000001–FFFFFE
rtl_433 decodes nothing antenna, frequency, wrong RF path, too little power send 1; 433.92 MHz receiver close by; ANT/GDO0 measurement fix antenna/supply; step through low powers gradually; do not switch to FSK
rtl_433 sees wrong data stale configuration, neighbouring sensor info, hex 1, ID filtering in the receiver compare IDs and force send 1 in an isolated spot
Car does not see known IDs unconfirmed profile, ECU requires learning, range VIN/markings/DTC; RTL-SDR reception at the car confirm the profile; perform LEARN; change position after measuring
LEARN stuck on one wheel used send instead of next info shows the active wheel next after confirming the step; send only forces TX
LEARN returned to NORMAL 60 s per wheel / 15 min session elapsed time, message and LED run mode learn 1 and consciously repeat from FL
After RL there is no next wheel the sequence completed NORMAL in info finish the car procedure and check DTC
Warning light stays on although RTL-SDR is OK ECU does not know the IDs, other profile/flags/procedure read IDs and DTC from diagnostics, not only SDR Clone IDs or LEARN; confirm the car profile; do not guess flags
High sleep consumption S2 Mini, LM317T, LED, dividers measure the whole board and regulator per POWER.md fix the supply; do not change the protocol
No TX after parking supply only from the lighter socket/ACC, brownout, NVS/CC1101 error does 3.3 V remain after the ignition goes off; log after restart, batt, info with an ignition-switched socket supply the lack of TX is expected; otherwise fix the supply
ACC does not change the interval feature disabled by default or wrong threshold PIN_ACC, voltage on GPIO OFF/ON build a protected input; never 12 V on GPIO

When the car does not receive

Diagnostic sequence:

  1. Prove local TX: send 1 + RTL-SDR/analyser.
  2. Prove the correct profile: VIN, sensor markings, car readout.
  3. Check IDs and order: info, Clone IDs, or one active wheel in LEARN.
  4. Check range: low power first, console/behind the glovebox, possibly the boot; without disassembling airbags or guessing the ECU location.
  5. Only then analyse flags: compare with a recording of the original sensor in the same mode. There is no confirmed low-battery bit — do not set it.
  6. If there is no measurement or data, stop the test. Random changes add new variables and are not a diagnosis.