Validation

One command without hardware

bash tools/check_all

The script runs the Python self-test, native tests, the full ESP32 build, cppcheck, fetching the pinned sources (on first run), and CU8 decoding by the real rtl_433. Logs: artifacts/validation/. Every stage has pipefail, and an error ends the script with a non-zero code.

A reproducible alternative:

docker build -t tpms-rc .
docker run --rm -v "$PWD/artifacts:/work/artifacts" tpms-rc

Results from 2026-10-28

Environment: Linux, Python 3.14.4 on the host test; PlatformIO 6.1.18; espressif32 8.0.0; Arduino ESP32 3.3.12; SmartRC CC1101 commit de6757ef633b3e626dae5c7835cdb66ab53f9a1d; rtl_433 commit 406f9a3…; rtl_433_tests commit 1aa8c29…. Full SHAs are in PROTOCOL.md.

Command Result
pio test -e native 24/24 PASS — frame, four independent vectors, negative tests, NVS, console parsing (NaN/ranges), fake clock/radio, Clone IDs, LEARN, SINGLE, ACC, restart
pio run -e esp32s2mini PASS, own warnings treated as errors (-Werror)
pio check -e native ... --fail-on-defect=low PASS, 0 defects after the struct initialisation fix
python3 tools/tpms_frame.py --self-test PASS, capture + 500 frames
tools/verify_rtl433.sh PASS, 64/64 reference records; 3/3 synthetic; 3/3 negative rejected
git diff --check PASS
bash tools/package_release.sh PASS, ESP32-S2 image with the bootloader at 0x1000 and a SHA-256 manifest

Reference data: each of gfile001…gfile004 produced exactly 16 matching records, with the expected ID/flags/pressure/temperature. The synthetic frames 2FC871/260 kPa/73 F, 3495AC/220 kPa/23 F and ABCDEE/262.5 kPa/75 F were decoded by an independent rtl_433. Damaged Manchester, a wrong sum, and truncation produced no EG53MA4 record.

Coverage matrix

Layer Automated Physical RTL-SDR Physical CC1101 Car
fields, checksum, quantisation done not needed for the field not needed confirmation of ECU interpretation
Manchester/preamble/length done not done not done not done
real recordings → rtl_433 done, 64/64 n/a n/a n/a
synthetic CU8 → rtl_433 done n/a bypasses hardware n/a
CC1101 registers/tail/power/frequency code audit required required required
NVS, IDs, intervals, modes done; NVS emulated with a blob a restart test is required required required
LEARN FL→FR→RR→RL state machine PASS auxiliary required not done
consumption/brownout/ACC ACC in the state machine; no measurements n/a required required

There is no basis for a "validated" label. Gitea Actions has a workflow, but the runner state and the remote CI result must be checked; a local PASS is not pretend CI.

HIL checklist — requires a user and hardware

CC1101 + analyser/RTL-SDR

  • Read the registers after initialisation: OOK, 433.92 MHz, fixed 30 B, SYNC_MODE=0, no CRC/Manchester/whitening/FEC/append.
  • On GDO0/ANT confirm exactly 30 B, a ~120 µs chip, a full last chip, and no hardware preamble/sync/CRC/extra bytes.
  • Record TX-ERR/underflow; there should be none on a correct RF path.
  • Measure the frequency and relative power at −10 dBm; do not assume the calibration of a cheap module. Do not raise the PA unnecessarily.
  • send 1…send 4: RTL-SDR decodes the correct IDs, 260 kPa and flags.
  • Repeat after a reset and 10 deep sleep cycles.

NVS and inputs

  • Set your own IDs/pressures/RF, disconnect power for >1 min, and re-check info and transmission.
  • Verify rejection of a duplicate ID, a bad power, and a bad interval.
  • factory YES restores 260 kPa and the default RF.
  • Brownout/crank on a protected supply: no hang or configuration damage; write settings only after the supply stabilises.
  • If ACC is installed: measure the GPIO voltage for OFF/ON/transients, check the intervals and automatic resumption after ACC ON. Skip without ACC.

The specific Opel Astra J

  • Confirm the profile via VIN/markings/diagnostics before transmitting.
  • Clone IDs: reception of the four known IDs without assuming learning will vanish.
  • New IDs: full learning FL→FR→RR→RL with one active wheel.
  • DTC and TPMS data read before/after; record the ECU version and procedure.
  • Position test: centre console/behind the glovebox, possibly the boot; while parked, without guessing the receiver location.
  • A tyre gauge check of all wheels before and after. Do not perform the test as a road drive with the simulator in place of a working TPMS.

Artifacts and flashing

bash tools/package_release.sh

The artifacts/release/ directory:

File Address
bootloader.bin 0x1000 — the address for ESP32-S2, not 0x0 as in ESP32-C3
partitions.bin 0x8000
boot_app0.bin 0xE000
firmware.bin 0x10000
firmware-full.bin 0x0 — the full 4 MB image
firmware.elf debug/symbols, do not flash it
SHA256SUMS, BUILD-INFO.txt integrity and version check

The full image erases the previous flash while writing the whole area; NVS in that partition may be lost — write down your IDs before updating with the full image. Updating only the application firmware.bin at 0x10000 usually preserves NVS, but before a release the user should test it on their own module.

PORT=/dev/ttyACM0 bash tools/flash_release.sh
(cd artifacts/release && sha256sum -c SHA256SUMS)

Do not flash an image from another toolchain blindly. The RC contains no physical update test or car test.